Auto Synchronizing one generating set with the mains (including AMF function). When the 6000 Series panel is operating in Automatic Mains Failure mode the controller waits for a remote start signal to indicate that the mains have failed.

Tải tài liệu

Thông tin chi tiết

Generating set parameter displays (2 X 4 line LCD display)

 AC voltage phase to phase and phase to neutral

(on 3 phases)

AC current (on each of 3 phases)

Frequency

CosF (power factor) average

kW - total + per phase

kVAr - total + per phase

kWh - total

% Voltage difference between bus and generator

Phase shift

Frequency slip

Hours run

Coolant temperature

Lube oil pressure

DC voltage

Bus parameter displays

 AC voltage (on a single phase)

AC voltage/frequency within limits indicator

Operator controls

 Off/auto/test/run control switch

Emergency stop pushbutton (lockdown)

Membrane keypad with tactile feedback

AC voltage adjust - manual and automatic

Engine speed adjust - manual and automatic

System controls

3 attempt start counter

Cool down delay

Pre-glow delay

Remote start capability

Check synch relay

Reverse power relay

Manual synchronizing

Automatic synchronizing

Automatic load sharing control

Automatic loading and unloading ramp controller

Automatic mains failure controller

Load sequencing control

Static battery charger (5amp) 220/240 Volt AC

Quadrature droop kit

Shutdowns and alarms

 High coolant temperature shutdown

Low oil pressure shutdown

Overspeed shutdown

Fail to start shutdown

Emergency stop operated

Reverse power shutdown

Overvoltage shutdown

Undervoltage shutdown or alarm

Overfrequency shutdown

Underfrequency shutdown or alarm

Alternator loss of excitation alarm

Fail to synchronize alarm

Battery overvoltage shutdown or alarm

Battery undervoltage alarm

Bus overvoltage alarm

Bus undervoltage alarm

Bus underfrequency alarm

Bus overfrequency alarm

Bus load surge

Spare fault channels, up to 3:

– Low coolant temperature alarm

– Low fuel level shutdown or alarm

– Low coolant level shutdown

Status indicators

 Load switch status indicator

General switch status indicator

Fault log memory

Password security

Interface to remote monitoring package